Incidence of weak D in blood donors typed as D positive by the Olympus PK 7200

Publications

Share / Export Citation / Email / Print / Text size:

Immunohematology

American National Red Cross

Subject: Medical Laboratory Technology

GET ALERTS SUBSCRIBE

ISSN: 0894-203X
eISSN: 1930-3955

DESCRIPTION

3
Reader(s)
3
Visit(s)
0
Comment(s)
0
Share(s)

SEARCH WITHIN CONTENT

FIND ARTICLE

Volume / Issue / page

Archive
Volume 37 (2021)
Volume 36 (2020)
Volume 35 (2019)
Volume 34 (2018)
Volume 33 (2017)
Volume 32 (2016)
Volume 31 (2015)
Volume 30 (2014)
Volume 29 (2013)
Volume 28 (2012)
Volume 27 (2011)
Volume 26 (2010)
Volume 25 (2009)
Volume 24 (2008)
Volume 23 (2007)
Volume 22 (2006)
Volume 21 (2005)
Volume 20 (2004)
Volume 19 (2003)
Volume 18 (2002)
Volume 17 (2001)
Volume 16 (2000)
Volume 15 (1999)
Volume 14 (1998)
Volume 13 (1997)
Volume 12 (1996)
Volume 11 (1995)
Volume 10 (1994)
Volume 9 (1993)
Volume 8 (1992)
Volume 7 (1991)
Volume 6 (1990)
Volume 5 (1989)
Volume 4 (1988)
Volume 3 (1987)
Related articles

VOLUME 21 , ISSUE 4 (December 2005) > List of articles

Incidence of weak D in blood donors typed as D positive by the Olympus PK 7200

Candace Jenkins / Susan T. Johnson / Daniel B. Bellissimo / Jerome L. Gottschall

Keywords : incidence of weak D, anti-D typing reagents

Citation Information : Immunohematology. Volume 21, Issue 4, Pages 152-154, DOI: https://doi.org/10.21307/immunohematology-2019-411

License : (Transfer of Copyright)

Published Online: 28-April-2020

ARTICLE

ABSTRACT

The incidence of weak D has been reported to be between 0.23 and 0.5 percent in Europe and 3.0 percent in the United States. All studies were performed before the introduction of monoclonal anti-D reagents. Using current commercial reagents, this study evaluated D+ samples for the presence of weak D. D+ donors, typed by the Olympus PK 7200, using diluted monoclonal blend anti-D and diluted polyclonal anti-D, were selected by sampling batches of 100 to 200 samples from the previous day’s collection. Anti-D reagents used on the Olympus PK 7200 are required to detect RBCs with the weak D phenotype which do not agglutinate at immediate spin (IS) when tested with polyclonal anti-D by manual tube methods. More than 95 percent of donors tested were Caucasian. Using tube tests with two different monoclonal blend anti-D reagents and one polyclonal anti-D typing reagent, the presence or absence of the D antigen was evaluated after the IS reading. Donors found negative or weakly positive (< 2+) at IS were further typed for weak D by the IAT. The weak D samples were RHD genotyped by allele-specific PCR. Of 1005 donors tested, 4 (0.4%) were classified as weak D by one or more anti-D reagents. Polyclonal anti-D reagent demonstrated weaker reactions when compared with the monoclonal blends. All weak D samples were found positive for exon 4, intron 4, and exon 10, a finding consistent with most D+ samples. The incidence of weak D found in this study is not significantly different from that found in earlier studies using polyclonal anti-D reagents.