An improved method for removal of red cell-bound immunoglobulin using chloroquine solution

Publications

Share / Export Citation / Email / Print / Text size:

Immunohematology

American National Red Cross

Subject: Medical Laboratory Technology

GET ALERTS SUBSCRIBE

ISSN: 0894-203X
eISSN: 1930-3955

DESCRIPTION

6
Reader(s)
6
Visit(s)
0
Comment(s)
0
Share(s)

SEARCH WITHIN CONTENT

FIND ARTICLE

Volume / Issue / page

Archive
Volume 37 (2021)
Volume 36 (2020)
Volume 35 (2019)
Volume 34 (2018)
Volume 33 (2017)
Volume 32 (2016)
Volume 31 (2015)
Volume 30 (2014)
Volume 29 (2013)
Volume 28 (2012)
Volume 27 (2011)
Volume 26 (2010)
Volume 25 (2009)
Volume 24 (2008)
Volume 23 (2007)
Volume 22 (2006)
Volume 21 (2005)
Volume 20 (2004)
Volume 19 (2003)
Volume 18 (2002)
Volume 17 (2001)
Volume 16 (2000)
Volume 15 (1999)
Volume 14 (1998)
Volume 13 (1997)
Volume 12 (1996)
Volume 11 (1995)
Volume 10 (1994)
Volume 9 (1993)
Volume 8 (1992)
Volume 7 (1991)
Volume 6 (1990)
Volume 5 (1989)
Volume 4 (1988)
Volume 3 (1987)
Related articles

VOLUME 10 , ISSUE 1 (March 1994) > List of articles

An improved method for removal of red cell-bound immunoglobulin using chloroquine solution

Angela E. Beaumont / R. Stamps / D.J. Booker / R.J. Sokol

Citation Information : Immunohematology. Volume 10, Issue 1, Pages 22-24, DOI: https://doi.org/10.21307/immunohematology-2019-815

License : (Transfer of Copyright)

Published Online: 22-November-2020

ARTICLE

ABSTRACT

In some patients with autoimmune hemolytic anemia or hemolytic disease of the newborn, the red cells are so heavily coated with immunoglobulin that phenotyping cannot be carried out unless the antibody is removed without destroying the red cell antigens. Studies were performed initially to determine the optimum conditions for removal of immunoglobulin from red blood cells (RBCs) using chloroquine. Group O, R1r RBCs were coated with serial dilutions of anti-D; aliquots were incubated in chloroquine diphosphate (CDP) solution (200 g/L, pH 5.0) at 18°C, 25°C, 30°C, and 37°C, and tested by the antiglobulin technique at intervals of 30 minutes for up to 2 hours, the results being expressed as titration scores. These studies showed that antibody removal was much more efficient at 30°C and 37°C than at 18°C or 25°C. A further series of experiments was then carried out to assess the effect of chloroquine on red cell antigenicity. A 5 percent suspension of RBCs heterozygous for C, D, and E antigens, and for Kell, Duffy, and Kidd antigens, was incubated at 30°C and at 37°C in chloroquine solution. Aliquots were removed at 30-minute intervals for up to 2 hours, tested with serial dilutions of the appropriate antisera, and titration scores obtained. The antigens were well preserved after two hours of chloroquine treatment at 30°C. However, when treatment was performed at 37°C, anitigenicity had markedly deteriorated by 60 minutes, although the antigens were still reasonably well preserved (except for Jkb) at 30 minutes. It is therefore recommended that treatment with chloroquine solution prior to typing RBCs heavily coated with antibody should be carried out for 90 minutes at 30°C or for not more than 30 minutes at 37°C.