Design of Monitoring System for Rural Drinking Water Source Based on WSN

Publications

Share / Export Citation / Email / Print / Text size:

International Journal of Advanced Network, Monitoring and Controls

Xi'an Technological University

Subject: Computer Science, Software Engineering

GET ALERTS

eISSN: 2470-8038

DESCRIPTION

5
Reader(s)
16
Visit(s)
0
Comment(s)
0
Share(s)

SEARCH WITHIN CONTENT

FIND ARTICLE

Volume / Issue / page

Related articles

VOLUME 2 , ISSUE 4 (December 2017) > List of articles

Design of Monitoring System for Rural Drinking Water Source Based on WSN

Zexin Lin / Weixing Wang * / Huili Yin / Sheng Jiang / Guohui Jiao / Jieping Yu

Keywords : Wireless sensor network, Water quality monitoring, Soil monitoring, Rural drinking water, Water source

Citation Information : International Journal of Advanced Network, Monitoring and Controls. Volume 2, Issue 4, Pages 5-9, DOI: https://doi.org/10.1109/iccnea.2017.106

License : (CC BY-NC-ND 4.0)

Published Online: 23-April-2018

ARTICLE

ABSTRACT

In order to solve the existing traditional rural drinking water monitoring in a lot of manpower, material resources, real-time, this paper introduces a WSN based on the rural drinking water source monitoring system design, the system consists of five parts: water quality monitoring, soil monitoring node node, node, routing node and gateway server. Water quality monitoring node, soil monitoring nodes send the collected data to the gateway node through the wireless module sent directly, or through the routing gateway node to the gateway node, each node of the data collection, unified by the GPRS module to upload server. The system can periodically detect the water quality and the important indicators of the soil in the rural water sources, and combine the water pollution with the soil non-point source pollution to realize on-line monitoring and provide guidance for pollution control. Network test shows that the designed system can realize data acquisition and remote transmission, stability, range of dissolved oxygen system for 1.09%~1.86% acquisition error, pH error is in the range of 0.64%~1.68%, Cu concentration in the range of error is 1.98%~2.22%, Cu concentration in the range of error is 1.58%~ 2.01%.

Content not available PDF Share

FIGURES & TABLES

REFERENCES

Xianglan Cao. Cause analysis and treatment of rural water pollution[J]. Modern rural science and technology, 2014(03):68.

 

Tao Jiang, Gang Chen. Analysis and research of rural drinking water safety [J]. Heilongjiang Science and Technology of Water Conservancy, 2014(09):261-262.

 

Shoufeng Zhang.Problems and optimization methods of water quality environmental monitoring [J]. Technology and enterprise, 2015(12):102.

 

Long Hui. Research on Development of Wireless Sensor Networks[J]. Microcontrollers & Embedded Systems, 2011(06):9-12.

 

Zhuojing Yang, Hongzhi Sun, Chenghong Ren. Overview of application technology in Wireless Sensor Networks [J]. China Science and Technology Information, 2010(13):127-129.

 

Gao Juan, Hua Luo, Hua Liping, etc. Analysis of Surface Water Quality Monitoring Condition and Its Countermeasures[J]. Journal of Capital Normal University(Natural Science Edition), 2006(01):75-80.

 

CHEN Yan, YAN Yun-hao, TAN Ting, etc.Design of multi-parameter water quality monitoring terminal based on WSNs[J]. Transducer and Microsystem Technologies, 2014(10):83-86.

 

JIANG Peng. Survey on Key Technology of WSN-Based Wetland Water Quality Remote Real-Time Monitoring System [J]. Chinese Journal of Sensors and Actuators, 2007(01):183-186.

 

Weijiang Ma. The Design of Aerodynamics Data Acquisition System Based on STM32[D]. Southwest Jiao Tong University, 2010.

 

Li Liangbin, Jiang Sheng, Wang Weixing, etc. Design of wireless sensor network node for monitoring water quality of rural water supply plant[J]. Journal of Hunan Agricultural University(NaturalSciences), 2016(02):212-216.

 

Xingyi Electronic Technology Co., Ltd.. ATK-S1216F8-BD Module user manual [Z]. 2016.

 

EXTRA FILES

COMMENTS