Article | 01-October-2019
(volume) and reduce losses, but the same will bring resonance problems. In this paper, a harmonic control strategy of micro-grid inverter based on PI control, multi-resonance control and LCL constant power control is proposed, which is used in the process of grid-connected control of micro-grid inverter to further reduce and net voltage of the total harmonic distortion rate, get better power of the grid.
II.
MATERIAL AND METHODS
A.
Principle block diagram of multi resonance LCL harmonic suppression
Jingwen Chen,
Xin Zhou,
Hongshe Dang
International Journal of Advanced Network, Monitoring and Controls, Volume 3 , ISSUE 3, 23–28