local metakaolin (calcined Soorh at 800°C for 2 hours duration) with dosages range; 5% to 25% with increment of 5% (by weight of cement). The investigation revealed that concrete made with 15% replacement of ordinary Portland cement (OPC) with locally developed metakaolin (MK) has significant influance on workability, compressive strength, ultrasonic pulse velocity measurements and drying shrinkage of concrete as compared to OPC concrete.
Abdullah SAAND,
Manthar Ali KEERIO,
Daddan khan BANGWAR
Architecture, Civil Engineering, Environment, Volume 10 , ISSUE 2, 115–122